Technical and safety information
The manufacturer's English SDS advises against private or household use of this reference. For delivery to other EU countries, checkout is limited to professional buyers with a validated EU VAT number. Dispatch requires destination-language safety documentation and chemical transport checks.
- Carrier
- Solvent
- Chemical base
- Cera
- Colour
- Transparente
- Pack format
- Drum 20 L
- Minimum order
- 1 envase
CLP hazard and safety information
English SDS revision: 2026-02-06
Use restriction: The manufacturer's SDS advises against private or household use.
Signal word: Danger
Hazard statements
- H226: Flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H336: May cause drowsiness or dizziness.
Precautionary statements
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P261: Avoid breathing mist/vapours.
- P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
- P370+P378: In case of fire: Use dry sand, extinguishing powder or alcohol-resistant foam to extinguish.
- P403+P233: Store in a well-ventilated place. Keep container tightly closed.
Supplemental hazard information
- EUH066: Repeated exposure may cause skin dryness or cracking.
This excerpt follows section 2.2 of the linked English SDS. Consult the full SDS and the product label before use. Request the official SDS and label in your destination country's language before dispatch; include the Tectyl reference, destination country and order number.
Documents
Technical Data Sheet (English) Application guide Safety Data Sheet (English)Technical documents are served by Coapsys from the official Tectyl Europe source.
Tectyl 502-C is a solvent cutback, soft wax base, corrosion preventive compound. Tectyl 502-C is designed to protect the insides of gearboxes, without removal after installation. Tectyl 502-C is designed to protect parts in indoor and covered storage and shipment. Tectyl 502-C is designed to protect ferrous and non-ferrous parts for indoor or covered storage and during shipment. Tectyl 502-C cures to a dark amber, transparent, soft greasy film.
Benefits and application considerations
- Superior Protection At the recommended DFT Tectyl 502-C will protect against corrosion during storage, domestic and overseas transport.
- Processing Tectyl 502-C is easy to apply and easy to remove, when no longer needed.
- Economical With a DFT of only 50 microns, Tectyl 502-C can protect a big surface with just little amount of the product.
Technical characteristics
- Carrier
- Solvent
- Recommended Dry Film Thickness — Over metal profile
- 25 µm
- Corrosion — ISO 9227 NSS (min. days)
- 7 days
- Humidity — Humidity; 100 % RH; @ 40°C; ISO 6270-2 CH (Q-Panels, Type R, ASTM A1008)
- 40 days
- Protection Indoor — (min. months)
- 24 months
- Protection Outdoor — (min. months)
- 6 months
- MIL-PRF-16173E — Grade / class
- 2/2
Surface preparation
The maximum performance of Tectyl 502-C cutbacks can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. CorPro recommends that the metal substrate temperature is 10-35 °C at the time of product application. Direct contact of Tectyl 502-C with PVC can cause compatibility problems. Please test prior to use.
Application
Tectyl 502-C is formulated to be used as supplied. CorPro recommends that the ambient and product temperature be 10-35 °C at the time of product application. Do not thin Tectyl 502-C. Incorrect thinning will affect film build, dry time and product performance. Tectyl 502-C can be applied by low pressure air spray or dipping. Details on application can be found in the application chart.
Removal
Tectyl 502-C can in the wet phase be removed with Tectyl Biocleaner, Tectyl 150 or low-pressure steam. If dried and cured the film of Tectyl 502-C can be removed with Tectyl Biocleaner or Tectyl 150. When applied in a gearbox or similar application, Tectyl 502-C does not need to be removed and will dissolve in the oil.
Check the current official Technical Data Sheet and Safety Data Sheet before purchase or use. Coapsys can advise on product selection and application equipment.