Technical and safety information
Online Tectyl checkout is currently configured for Spain. For deliveries elsewhere in Europe, contact Coapsys to confirm availability and shipping before ordering.
- Carrier
- Solvent
- Chemical base
- Cera
- Colour
- Transparente
- Pack format
- Consultar formatos disponibles
- Minimum order
- Consultar
For current hazard statements, precautions and transport information, consult the official English Safety Data Sheet before purchase or use. This page is not a substitute for the product label.
Documents
Technical Data Sheet (English) Safety Data Sheet (English)Technical documents are served by Coapsys from the official Tectyl Europe source.
Tectyl TM 400-C is a solvent cutback, wax base, corrosion preventive compound. Tectyl TM 400-C is designed to protect metal surfaces against corrosion in long-term indoor or short- term outdoor exposure and during domestic and overseas shipment. Tectyl TM 400-C cures to a dark amber colored, waxy, transparent, firm film.
Benefits and application considerations
- Excellent protection Tectyl 400-C protects your parts during storage, domestic and overseas transport against corrosion.
- Economical solution With the thin layer of only 25 microns a large area can be protected against corrosion.
- Easy application Tectyl 400-C can be applied by low pressure air spray, but also by dipping the parts in a bath filled with Tectyl 400-C.
Technical characteristics
- Carrier
- Solvent
- Recommended Dry Film Thickness — Over metal profile
- 25 µm
- Corrosion — ISO 9227 NSS (min. days)
- 8 days
- Humidity — Humidity; 100 % RH; @ 40°C; ISO 6270-2 CH (Q-Panels, Type R, ASTM A1008)
- 21 days
- Protection Indoor — (min. months)
- 24 months
- Protection Outdoor — (min. months)
- 6 months
Surface preparation
The maximum performance of Tectyl 400-C can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. CorPro recommends that the metal substrate temperature is 10-35 °C at the time of product application.
Application
Tectyl TM 400-C is formulated to be used as supplied. CorPro recommends that the ambient and product temperature be 10-35 °C at the time of product application. Do not thin Tectyl 400-C. Incorrect thinning will affect film build, dry time and product performance. If the product thickens due to cold storage or loss of solvent during use, contact CorPro. Tectyl 400-C can be applied by low pressure air spray or dipping. Details on application can be found in the application chart.
Removal
Tectyl 400-C can in the wet phase be removed with Tectyl Biocleaner, Tectyl 150 or low-pressure steam. If dried and cured Tectyl 400-C can be removed with Tectyl Biocleaner or Tectyl 150.
Check the current official Technical Data Sheet and Safety Data Sheet before purchase or use. Coapsys can advise on product selection and application equipment.