Technical and safety information
Online Tectyl checkout is currently configured for Spain. For deliveries elsewhere in Europe, contact Coapsys to confirm availability and shipping before ordering.
- Carrier
- Solvent
- Chemical base
- Aceite
- Colour
- Transparente
- Pack format
- Consultar formatos disponibles
- Minimum order
- Consultar
For current hazard statements, precautions and transport information, consult the official English Safety Data Sheet before purchase or use. This page is not a substitute for the product label.
Documents
Technical Data Sheet (English) Application guide Safety Data Sheet (English)Technical documents are served by Coapsys from the official Tectyl Europe source.
Tectyl 472 is a solvent cutback, water displacing, oil-based corrosion preventive compound and penetrant. Tectyl 472 is used to protect industrial parts during long-term indoor or covered storage, and during domestic shipment. Tectyl 472 cures to an ultra-light, transparent oil film.
Benefits and application considerations
- Excellent protection Tectyl 472 protects your parts during storage and domestic transport against corrosion.
- Economical solution With the thin layer of only 3 microns a large area can be protected against corrosion.
- Easy application Tectyl 472 can be applied by low pressure air spray, but also by dipping the parts in a bath filled with Tectyl 472.
Technical characteristics
- Carrier
- Solvent
- Recommended Dry Film Thickness — Over metal profile
- 3 µm
- Corrosion — ISO 9227 NSS (min. days)
- 5 days
- Humidity — Humidity; 100 % RH; @ 40°C; ISO 6270-2 CH (Q-Panels, Type R, ASTM A1008)
- 75 days
- Protection Indoor — (min. months)
- 6 months
Surface preparation
The maximum performance of Tectyl 472 can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. CorPro recommends that the metal substrate temperature is 10-35 °C at the time of product application.
Application
Tectyl 472 is formulated to be used as supplied. CorPro recommends that the ambient and product temperature be 10-35 °C at the time of product application. Do not thin Tectyl 472. Incorrect thinning will affect film build, dry time and product performance. If the product thickens due to cold storage or loss of solvent during use, contact CorPro. Tectyl 472 can be applied by low pressure air spray or dipping. Details on application can be found in the application chart.
Removal
Tectyl 472 can in the wet phase be removed with Tectyl Biocleaner, Tectyl 150 or low-pressure steam. If dried and cured Tectyl 472 can be removed with Tectyl Biocleaner or Tectyl 150.
Check the current official Technical Data Sheet and Safety Data Sheet before purchase or use. Coapsys can advise on product selection and application equipment.