Skip to Content

Tectyl™ 472

Referencia TECTYL-472
Price on request

Confirm pack format, quantity and application with our technical team.

Ask for price and availability
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Technical and safety information

Chemical product

Online Tectyl checkout is currently configured for Spain. For deliveries elsewhere in Europe, contact Coapsys to confirm availability and shipping before ordering.

Carrier
Solvent
Chemical base
Aceite
Colour
Transparente
Pack format
Consultar formatos disponibles
Minimum order
Consultar

For current hazard statements, precautions and transport information, consult the official English Safety Data Sheet before purchase or use. This page is not a substitute for the product label.

Tectyl 472 is a solvent cutback, water displacing, oil-based corrosion preventive compound and penetrant. Tectyl 472 is used to protect industrial parts during long-term indoor or covered storage, and during domestic shipment. Tectyl 472 cures to an ultra-light, transparent oil film.

Benefits and application considerations

  • Excellent protection Tectyl 472 protects your parts during storage and domestic transport against corrosion.
  • Economical solution With the thin layer of only 3 microns a large area can be protected against corrosion.
  • Easy application Tectyl 472 can be applied by low pressure air spray, but also by dipping the parts in a bath filled with Tectyl 472.

Technical characteristics

Carrier
Solvent
Recommended Dry Film Thickness — Over metal profile
3 µm
Corrosion — ISO 9227 NSS (min. days)
5 days
Humidity — Humidity; 100 % RH; @ 40°C; ISO 6270-2 CH (Q-Panels, Type R, ASTM A1008)
75 days
Protection Indoor — (min. months)
6 months

Surface preparation

The maximum performance of Tectyl 472 can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. CorPro recommends that the metal substrate temperature is 10-35 °C at the time of product application.

Application

Tectyl 472 is formulated to be used as supplied. CorPro recommends that the ambient and product temperature be 10-35 °C at the time of product application. Do not thin Tectyl 472. Incorrect thinning will affect film build, dry time and product performance. If the product thickens due to cold storage or loss of solvent during use, contact CorPro. Tectyl 472 can be applied by low pressure air spray or dipping. Details on application can be found in the application chart.

Removal

Tectyl 472 can in the wet phase be removed with Tectyl Biocleaner, Tectyl 150 or low-pressure steam. If dried and cured Tectyl 472 can be removed with Tectyl Biocleaner or Tectyl 150.

Check the current official Technical Data Sheet and Safety Data Sheet before purchase or use. Coapsys can advise on product selection and application equipment.